- High performance and long term reliability
- Mounting “snap-on” DIN rail (EN50022)
- ANALOG output (4-20 mA, 0-20 mA, 0-5 Vdc, 0-10 Vdc)
- Configuration and calibration from the front panel executable with certificates of transducers, or with known weights
- 2 logic inputs and 2 relay outputs
- Outputs RS232, Modbus RTU and ASCII protocols
- The size of a width contained allow to place a large number of transmitters within the electrical panels of automation
- Interfacing with barriers Intrinsically Safe for use in hazardous areas
Sensor supply: | 4 Vdc (max 4 cells of 350 Ohm) |
Measuring range: | -4 To +4 mV / V |
Input sensitivity: | 00:02 V / division |
Linearity: | <0.01% FS |
Temperature drift: | <0.001% FS / ° C |
Display: | 5-digit, 7-segment red LED, height 7 mm |
Status LEDs: | 2 red |
A / D converter: | 24 bit |
Internal resolution: | 16,000,000 points |
Displayable resolution: | 60,000 displayable divisions on net weight |
Value divisions (selectable): | 0001 ÷ 50 |
Filter: | selectable 0.2 to 25 Hz |
Keyboard: | 3 mechanical buttons (behind the red door) |
Power tool: | 24 VDC ± 10% – Power consumption 2 W |
Operating temperature: | -10 To + 50 ° C (humidity max 85% non-condensing) |
Storage temperature: | -20 To + 60 ° C |
Logic outputs: | 2 optisolate; MAX 24 VDC / 100 mA each |
Logic inputs: | 2 opto-isolated 24 VDC PNP (external power supply) |
Serial Ports: | RS232 half duplex protocol ASCII or Modbus RTU |
Baud rate: | 2400 ÷ 115200 selectable |
Analog output: | optically isolated 16-Bit |
Voltage: | 0 ÷ 5 / 10V (R min10 K Ohm) |
Current: | 0/4 to 20mA (max R 300 Ohm) |
Linearity: | <0,03% FS |
Temperature drift: | <0.002% FS |
Regulatory Compliance: | EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety |
Electrical connections: | Screw terminal blocks 5.08 mm pitch |