• YAKOTEC
  • AUTEC
  • I-ROBO
  • WANSHSIN
  • TOGAMI
  • Thương hiệu oriental motor
  • Thương hiệu SanyoDenki
  • Thương hiệu Mitsubishi
  • Thương hiệu Itoh Denki
  • Thương hiệu Zhongda Motor
  • Thương hiệu Ebm papst
DAT400S  PAVONE SISTEMI

DAT400S PAVONE SISTEMI

Mã sản phẩm: DAT400S
Tên thiết bị: DAT400S PAVONE SISTEMI
Xuất xứ: ITALIA
Tình trạng:
Liên hệ:
Giá: Liên Hệ

DPC VIỆT NAM CHUYÊN CUNG CẤP DAT400S CỦA HÃNG  PAVONE SISTEMI

 

DAT 400 S

 

Weighing atex and stainless steel

 

dat400s

 

- Configuration and calibration from the front panel, or via the serial port with the program Inovation ™ (MS Windows)
- Function of upload and download programming with TESTER 1006
- Linearization on 10 points
- RS232 serial output oRS422 / RS485 MODBUS RTU or ASCII protocols selectable
- ATEX, IP66 / 67, area 2.22
- Connected directly to the fieldbus PROFIBUS and DeviceNet option card
- Optional analogue output (0 to 20mA, 4 to 20mA, 0 to 5V, 0 to 10V) adjustable on the whole measuring range

 

resize DAT400S

 

TECHNICAL DAT 400 S

Sensor supply: 5 V (max 6 cells of 350 Ohm)
Measuring range: -0.5 to +3.5 mV / V (optional from -3.9 to +3.9 mV / V)
Input sensitivity: 0:02 microV / division
Linearity: <0.01% of full scale
Temperature drift: <0.001% FS / ° C
Status LEDs: 4 red
A / D converter: 24 bit
Displayable resolution: 60,000 displayable divisions on net weight
Decimals set: 0.0; 0:00; 0.000
Filter: selectable from 0.1 to 25 Hz
Power tool: 24 VDC ± 15% – power consumption 5 W
Operating temperature: -10 / + 40 ° C (humidity max 85% non-condensing)
Storage temperature: -20 / + 50 ° C
Logic outputs: 2 relay (contact) MAX 24 VDC / 100 mA each.
Logic inputs: 2 opto-isolated 24 VDC PNP (external power supply)
Serial port: USB, RS232C or RS422 / RS485 with Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Communication with other fieldbus: CANopen, Modbus-Plus and other
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 selectable
Regulatory Compliance: EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for Electrical Safety
ATEX II 3 GD EEx nR IIC T6 IP65: EN 13463-1: 2003; EN 60529: 1991 + A1: 2000 IEC 60079-0: 2004; IEC 60079-15: 2005
Optional analogue output: Optically isolated 16-Bit, Voltage: 0 to 5 or 0 to 10V (R> 10 K Ohm); Current: 0 to 20 or 4 to 20 mA (R <300 Ohm); Linearity 0.03% of full scale
BCD output option: Via external modules
Protocol to fieldbus option: PROFIBUS, DEVICENET
AC power supply Optional: 115/230 VDC 50/60 Hz