Technical Data |
Case |
Ø 100mm, stainless steel 304S |
Degree of protection |
IP 65 per EN 60529 / IEC 529 |
Pressure connection |
G1/2B per EN 837-1, stainless steel 316Ti |
Sensing element |
< 4 bar stainless steel 316L, Measuring bridge: piezoresistive
> 4 bar stainless steel 17-7PH, Measuring bridge: thin film strain gauge |
Pressure and overpressure ranges |
see Technical Details page 05.0603 |
Electrical connection |
Terminal box, L-plug EN 175301-803 |
Signal output Power supply |
0/4 … 20 mA, 3-wire Ub = 12 … 30 V DC |
Load |
Rb [Ohm] = (Ub [V] – 17 [V] ) / 0,02 [A] |
Response time |
t < 10 ms |
Accuracy |
Linearity + hysteresis + repeatability < 0,3 % FS |
Display |
4½ digits LED-display, height of digits 14 mm, 2,5 mesures / s |
Power consumption |
P max = 2,2 W |
EMC-Directive |
2004/108/EC EN 61326 Emission (Group 1, Class B. Immunity, industrial locations) |
Permissible temperatures Tmin / Tmax |
Storage temperature – 30 … + 80°C
Ambient temperature – 20 … + 50°C
Medium temperature – 20 … + 80°C |
Temperature error |
Mean TK of zero < 0,2 % FS / 10 K
Mean TK of range < 0,2 % FS / 10 K |
Weight |
0,7 kg |