Service intended: Switching amplifier for inductive contacts to DIN 19234 for industrial applications where no protection against explosion is required.
Technical Data |
Case |
Polyamide 6,6, green |
Case dimensions |
B x H x D :50 x 75 x 100 mm |
Mounting |
Snap mounting on rail: 35 mm to EN 50022 |
Weather protection |
IP 20 to EN 60529 |
Wiring |
Screwed connections, Cable cross section : 0,5 … 2,5 mm2 |
Power supply |
AC voltage : 230 V / 50 – 60 Hz / 22 mA : 115 V / 50 – 60 Hz / 51 mA : 24 V/ 50 – 60 Hz / 43 mA DC voltage : 24 V / 30 mA |
DC voltage output |
for external units Power supply AC : 24 V DC +/- 10 % / 20 mA Power supply DC : auxiliary energy 1,4 V / 50 mA |
Control signals |
No load voltage : approx. 10 V DC Short circuit current : 4,5 mA ± 10 % Switching threshold : 1,8 mA ± 10 % Output impedance : 2200 Ohm, 100 nF ± 10 % |
Outputs |
Potential free change-over contact Pull in delay : 20 ms Drop out delay : 20 ms Breaking capacity : 1860 VA Breaking voltage : 250 V, 50 Hz / 100 V DC Breaking current : 8 A AC / 0,5 A DC |
Permissible temperatures Tmin / Tmax |
Ambient temperature: 0 … 70°C |
Please contact with Us when you would to support.